Applications

Microwave Sensor Applications

For Ironworks - OTHERS

Microwave Sensor Applications

Level Measurement of High Temperature Liquid Salt

Hot steel coil is passed through a cooling bath containing hyper-saline water. The Range Finder is used to control the level of the bath. The high temperature of the liquid and surrounding area makes measurement difficult for other measuring devices.
However, the Range Finder utilizes a guide pipe/waveguide and a reflector to locate the electronics away from the high temperature area – allowing simple installation without special cooling.